If required, return the sensor to an Authorized Instantel Representative for further testing.Check cables and connectors for wear, bent pins, or foreign debris.Refer to the section in this manual, Geophone Direct Hard Surface Mount Installation Instruction. Ensure that the orientation of the Geophone is correct, as per the given application, such as a ceiling installation.Was the sensor moved during the Sensor Check? This will result in a failed reading. When a Sensor Check error occurs, check the following for possible causes: Sensor Check does not compare the measured result against an external traceable reference sensor, nor does it test the entire electronic circuit that is integral to the sensor’s response. The Sensor Check is NOT a calibration check and cannot replace the annual calibration process. If a sensor was not level, or was upside down, the monitor would indicate a failed Sensor Check. The only purpose of the Sensor Check feature on Instantel vibration monitors, is to ensure that the sensors have been connected and installed correctly. The results of the Sensor Check and the associated information for each sensor, including Serial Number, Calibration Date, and Calibration Location, appear on the Event Report. Use the Sensor Check feature to determine if the attached sensors are connected, oriented, and working properly, or to ensure that the sensors match the current settings within the View/Edit Setup File menu if it has been set to Before or After an Event. Rugged design including a high-impact case with a fully sealed top panel, and non-corrosive connectors. Please refer to Chapter 9.5.1 of the Minimate Pro Operator Manual, page 9-29, for more information. Instantel® Micromate Vibration and Overpressure Monitor. In the confirmation dialog box, click OK.WARNING: Deleted events cannot be restored. Click a project’s arrow that contains the unit’s event data to delete.Please refer to Chapter 5.5.2 of the THOR Operator Manual, page 100, for more information. WARNING: Deleting an event, will delete all associated reports with it. Tip: To select multiple events, hold down CTRL on the keyboard and select the events. Select one or more events then right-click and select Delete Event(s).Please refer to Chapter 5.5.1 of the THOR Operator Manual, page 99, for more information. (Events with the Location Type Local are already copied onto the computer.) Select one or more events with the Location Type Unit, then right-click and select Create Local Copy of Event(s) and Log(s).Click a project’s arrow that contains the unit’s event data to copy.Local: A copy of the event file has been downloaded to the local computer and can be viewed permanently in THOR. Unit: The event file is stored on the unit and is being viewed temporarily in THOR. The Location attribute indicates where the event file resides. Use this function to store a copy of the event file(s) onto your local computer. Please refer to Chapter 5.4 of the THOR Operator Manual, page 98, for more information.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |